Mechanisms executive electric straight-forward MEP (general industrial execution)

Mechanisms of executive electric propulsion type MEP are designed to move the regulating bodies of reciprocating motion in systems of remote or automatic control. A typical example of use is the use with shut-off or shut-off valves, including cases where close closure is required in the end position. The mechanism, as a rule, is mounted directly on the regulating arm in any spatial position.

The operating mode of the mechanism is re-short-term with frequent start-ups S4 in accordance with GOST 183 with an inclusions frequency of up to 320 per hour (maximum incidence of up to 630 per hour, but not more than 1 hour per day) by up to 25% with loads on the output rod within From the nominal counter-acting up to 0.5 nominal attendant.

In the mechanism, one of the following types of position signaling unit can be installed:

  • The current position signaling unit BSPT-10 or BSPT-21
  • Inductive signaling unit BSPI-10
  • Block of signaling of position rheostatny BSPR-10
  • Block of limit switches BKV

Symbol

Nom. Effort, H

Voltage and frequency of power supply

Power consumption, W

Overall dimensions, mm

Weight, kg

MEP 2500/63-10

2500

220В 50Hz

45

270x208x470

13,5

MEP 2500/63-16
MEP 2500/63-25

110

MEP 2500/63-40
MEP 6300/75-25

6300

MEP 6300/125-40
MEP 6300/63-25

380В 50Hz

300x208x540

15

MEP 6300/63-63

300x208x644

16,5

MEP 2500/30-63

2500

220В 50Hz

270

370x300x455

22

MEP 10000/63-63

10000

220В 50Hz

110

260x205x540

20

MEP 16000/63-32

16000

MEP 16000/100-63
MEP 16000/40-16
MEP 20000/63-32

20000

MEP 20000/120-63
MEP 20000/160-63
MEP 20000/120-63

20000

380В 50Hz

270

260x205x540

28

MEP 16000/63-32

16000

MEP 20000/63-32

20000

MEP 20000/160-63
MEP 16000/100-63

16000

MEP 10000/63-63

10000

MEP 16000/40-16

16000

MEP 20000/63-63

20000

305

30

MEP 25000/10-100

25000

380В 50Hz

550

430x330x680

90

MEP 25000/16-160

430x330x740

95

MEP 25000/25-250

430x330x830

100

MEP 25000/25-100

430x330x680

90

MEP 25000/40-160

430x330x740

95

MEP 25000/63-250

430x330x830

100

MEP 25000/63-100

285

430x330x680

90

MEP 25000/100-160

430x330x740

95

MEP 25000/160-250

430x330x830

100

MEP 40000/63-100

40000

550

430x330x680

90

MEP 40000/100-160

430x330x740

95

MEP 40000/160-250

430x330x830

100

MEP 63000/25-100

63000

430x330x680

90

MEP 63000/40-160

430x330x740

95

MEP 63000/63-250

430x330x830

100

Climatic performance in accordance with GOST 15150:

  • У2 (ambient air temperature from minus 30 to plus 50 ºС, relative humidity of ambient air up to 95% at temperature plus 35 ºС and lower temperatures without condensation of moisture);
  • T2 (ambient air temperature from minus 10 to plus 50 ° C, relative humidity of the ambient air of 100% at a temperature of plus 35 ° C with condensation of moisture).

Degree of protection in accordance with GOST 14254-96: IP54 (shell type 2) ensures the operation of the mechanism in the presence of dust and water in the environment.

Electromagnetic actuating actuators MEP (explosion-proof version)

Mechanisms of MEP explosion-proof design are designed for operation in indoor and outdoor installations under a canopy in which explosive mixtures with explosive category IIB of group T4 can be formed, taking into account the requirements of Chapter 7.3 of the Electrical Installation Rules and other normative and technical documents determining the applicability of electrical equipment in explosive areas.

Symbol

Nom. Effort, H

Voltage and frequency of power supply

Power consumption, W

Overall dimensions, mm

Weight, kg

MEP 2500/63-160-IIBT4

2500

380В 50Hz

100

320x385x660

50

MEP 2500/25-63-IIBT4

320x385x550

47

MEP 6300/160-160-IIBT4

6300

320x385x660

50

MEP 6300/63-63-IIBT4

320x385x550

47

MEP 6300/10-63-IIBT4

52

MEP 6300/5-25-IIBT4
MEP 6300/63-160-IIBT4

345

320x385x660

MEP 2500/63-40-IIBT4

2500

100

270x250x440

15

MEP 6300/63-63-IIBT4

6300

210

270x250x500

16

MEP 6300/63-25-IIBT4

100

270x250x460

15

MEP 6300/125-25-IIBT4
MEP 6300/125-40-IIBT4
MEP 25000/10-100-IIBT4

25000

545

430x350x680

95

MEP 25000/16-160-IIBT4

430x350x740

97

MEP 25000/25-250-IIBT4

430x350x800

100

MEP 25000/25-100-IIBT4

430x350x680

95

MEP 25000/40-160-IIBT4

430x350x740

97

MEP 25000/63-250-IIBT4

370

430x350x680

95

MEP 25000/100-160-IIBT4

430x350x740

97

MEP 25000/160-250-IIBT4

430x350x800

100

MEP 40000/63-100-IIBT4

40000

545

430x350x680

95

MEP 40000/100-160-IIBT4

430x350x740

97

MEP 40000/160-250-IIBT4

430x350x800

100

MEP 63000/25-100-IIBT4

63000

430x350x680

95

MEP 63000/40-160-IIBT4

430x350x740

97

MEP 63000/63-250-IIBT4

430x350x800

100

In terms of resistance to the effects of climatic factors of the external environment, the MEP mechanisms of explosion-proof design correspond to the climatic performance and the category of UHL2 placement in accordance with GOST 15150-69 with temperature limitations.

In terms of protection from getting into the mechanism of solids (dust) and water penetration, the mechanism and the remote unit have the degree of protection IP54, shells of category 2 in accordance with GOST 14254-96.

Mechanisms executive electric multiple-roll MEM (general industrial execution)

The electric multi-turn actuators type MEM are designed to move the regulating bodies in remote or automatic control systems.

The operating mode of the mechanism is re-short-term with frequent start-ups S4 in accordance with GOST 183 with an inclusions frequency of up to 320 per hour (maximum incidence of up to 630 per hour, but not more than 1 hour per day) by up to 25% with loads on the output rod within From the nominal counter-acting up to 0.5 nominal attendant.

In the mechanism, one of the following types of position signaling unit can be installed:

  • The current position signaling unit BSPT-10 or BSPT-21
  • Inductive signaling unit BSPI-10 or BSPI-21
  • The signaling unit of the rheostat state BSPR-10 or BSPR-21
  • Switch block BV

Symbol

Nom. Effort, H

Voltage and frequency of power supply

Power consumption, W

Overall dimensions, mm

Weight, kg

MEM 16/63-10

16

380В 50Hz

210

250x164x330

14

MEM 16/160-25
MEM 16/400-63
MEM 40/63-10

40

125

300x230x350

22

MEM 40/160-25
MEM 40/400-63
MEM 40/25-10

200

23

MEM 40/63-25
MEM 40/160-63
MEM 100/63-10

100

MEM 100/160-25
MEM 100/400-63
MEM 100/25-10

545

25

MEM 100/63-25
MEM 100/160-63
MEM 100/250-250

1045

365x230x365

32

MEM 250/160-25

250

545

350x230x350

23

ЭМ 250/240-200

1900

520x445x470

48

MEM 100/63-10

100

24В

240

390x230x350

28

Mechanisms electric executive multi-plan MEM (explosion-proof design)

The electric multi-turn actuators type MEM are designed to move the regulating bodies in remote or automatic control systems.

Mechanisms of MEM explosion-proof design are designed for operation in indoor and outdoor installations under a canopy in which explosive mixtures with explosive category IIB group T4 can be formed, taking into account the requirements of Chapter 7.3 of the Electrical Installation Rules and other normative and technical documents determining the applicability of electrical equipment in hazardous areas.

Symbol

Nom. Effort, H

Voltage and frequency of power supply

Power consumption, W

Overall dimensions, mm

Weight, kg

MEM 16/63-10-IIBT4

16

380В 50Hz

200

265x250x350

20

MEM 16/160-25-IIBT4
MEM 16/400-63-IIBT4
MEM 40/1000-63-IIBT4

40

280

265x260x400

25

MEM 100/160-10-IIBT4

100

430

265x260x400

25

MEM 100/25-10-IIBT4

580

370x360x390

30

MEM 100/63-25-IIBT4
MEM 100/160-63-IIBT4
MEM 100/160-4-IIBT4

430

440x320x335

37

In the mechanisms of the electric multi-turn actuators MEM of the explosion-proof design, the remote power supply BP-26 installed in the explosion-proof zone is provided for supplying the output position sensor of the output unit (sensor unit BD-26 of the signaling unit BSPT-26).

In terms of its resistance to the effects of climatic factors of the external environment, the mechanism corresponds to the climatic performance of the UHL placement category 2 in accordance with GOST 15150-69, but for operation at temperatures from minus 50 ºС to plus 50 ºС and 95% relative humidity at 35 ºС and lower temperatures without condensation Of moisture. In terms of protection from the ingress of solid bodies (dust) and water into the mechanism, the mechanism and the remote unit have the degree of protection IP54, shells of category 2 in accordance with GOST 14254-96.

MyCounter - счётчик и статистика